Concox WeTrack lite (GV25)

Concox WeTrack lite (GV25)
Manufacturer: Jimi IoT (Concox)
Forum Discussion
Discontinued

Number of units

3186
Online
4074
Total
Supported in Wialon:
  • Remote management via GPRS
  • LBS
  • Modification of the "speed" parameter
  • Communication via TCP

The following data should also be added to Concox WeTrack lite (GV25) unit properties section of Wialon GPS tracking software :

Device type: Concox WeTrack lite (GV25)
Unique ID: imei

Specify the following parameters in configuration software or configuration Concox WeTrack lite (GV25) for use in Wialon Hosting :

Server port: 21564

4074 units of Concox WeTrack lite (GV25) device type are connected to Wialon Data Center. This represents 0.17% of all AVL Hardware connected.

Below chart represents the dynamic of connections in the last 30 days:

Parameter name Description Units
alarm

Alarm status:
0: normal
1: SOS
2: Power Cut Alarm
3: Vibration Alarm
4: Fence In Alarm
5: Fence Out Alarm
6: Over-speed Alarm
9: Moving Alarm
41: Harsh acceleration alarm
42: Sharp Left Turn
43: Sharp Right Turn

48: Harsh deceleration alarm

alarm_status

Alarm status:
0: Normal
1: Shock Alarm
2: Power Cut Alarm
3: Low Battery Alarm
4: SOS

mcc Mobile Country Code
mnc Mobile Network Code
lac Location Area Code
cell_id Cell Tower ID
voltage

Voltage degree 0-6:
0: Lowest power and power off
1: No enough power to dial a call or send messages.
2: Low power and alarm
3: Lower power but can work normally
3~6: Work in good condition

gsm GSM signal strength degree
alm1

Bitwise parameter (1 - ON, 1 - OFF):
bit1 - SMS Alarm
bit2 - Phone Alarm
bit3 - Network Alarm
bit4 - Displacement Alarm
bit5 - SMS Alarm
bit6 - Phone Alarm
bit7 - Network Alarm
bit8 - Vibration Alarm

alm2

Bitwise parameter (1- ON, 0 - OFF):
bit1 - SMS Alarm
bit2 - Phone Alarm
bit3 - Network Alarm
bit4 - Low Battery Alarm
bit5 - SMS Alarm
bit6 - Phone Alarm
bit7 - Network Alarm
bit8 - Low Battery Alarm

alm3

Bitwise parameter (1 - ON, 0 - OFF):
bit1 - SMS Alarm
bit2 - Phone Alarm
bit3 - Network Alarm
bit4 - Power Off Alarm
bit5 - SMSAlarm
bit6 - Phone Alarm
bit7 - Network Alarm
bit8 - Overspeed Alarm

sta1

Bitwise parameter (1 - ON, 0 - OFF):
bit1 - Disassembly Alarm Status
bit2 - Disassembly
bit5 - Remotely Disarm
bit6 - Manually Arm
bit7 - Automatically Arm
bit8 - Arm Status

dyd

Fuel/Electricity, Cutoff Status ( 1 - Valid, 0 - Invalid):
bit1 - Oil/Electricity connection
bit2 - Oil/Electricity cutoff
bit3 - Deferred execution caused by GPS unlocated
bit4 - Deferred execution caused by overspeed

sos_numN SOS number
center_num Center number
fence Fence
mode Mode