Vega NB-12

Vega NB-12
Manufacturer: Vega-Absolut
Forum Discussion

Number of units

0
Online
0
Total

The following data should also be added to Vega NB-12 unit properties section of Wialon GPS tracking software :

Device type: Vega NB-12
Unique ID: imei

Specify the following parameters in configuration software or configuration Vega NB-12 for use in Wialon Hosting :

Server port: 22577

0 units of Vega NB-12 device type are connected to Wialon Data Center. This represents 0% of all Asset trackers connected.

Below chart represents the dynamic of connections in the last 30 days:

Parameter name Description Units
fw_version

name and version of firmware

imsi

SIM card (SIM chip) identifier

iccid

SIM card (SIM chip) identifier

msg_number

message number

sq

signal quality from the station

earfcn

radio frequency channel number (absolute)

pcid

physical network address

rsrq

incoming signal quality (in centibels)

rssi

incoming signal strength indicator (in centibels)

snr

signal to noise ratio

reason

the reason for the formation of the data slice

  • alarm1 - the packet is generated by an alarm at the input "COUNT1* (this is why event initiates a communication session)
  • alarm2 - the packet is generated by an alarm at the "COUNT2" input (this is why event initiates a communication session)
  • cnfg - the package is generated forcibly by command from the configurator hall
  • sensor - the package is generated by the Hall sensor (based on this event
    communication session is initiated)
  • button - the package is generated by pressing a button (by this event
    communication session is initiated)
  • pulse limit - the packet was generated due to an alarm, since the number of pulses exceeds established thresholds
  • ow limit - the packet was generated due to a onewire alarm, since the temperature exceeds established thresholds
  • settings_change - confirmation of delivery of the package with settings (the "Send confirmation to the server about changing device settings" checkbox must be checked)

battery

battery charge percentage

temperature

device controller temperature

current

dependent current of the current loop interface

bat_drop

voltage value of the battery under control

states_magnetic

the presence of an external magnetic field, where “O” is absent, “1” exists

states_covr

flag for exceeding current loop interface current limits, specified in the settings ("0" - the limit is not exceeded, "1" - the limit is exceeded)

states_bde

flag of the presence of a critical battery voltage drop under
load

pulse_N_cnt

number of pulses at pulse input N

pulse_N_h

more than the specified number of pulses per period (0 - no
exceeding thresholds, 1 - exceeding recorded) at pulse input N

pulse_N_l

less than the specified number of pulses per period (0 - no
exceeding thresholds, 1 - exceeding recorded) at pulse input N

ow_N_temperature

sensor temperature value on the N-Wire bus

ow_N_temperature_h

threshold exceeding flag ("0" - no exceeding, "1" - thresholds exceeded) on the N-Wire bus

More devices from the manufacturer

Contact Wialon and achieve the most ambitious goals with telematics

Fill out a request form to get started with Wialon

Step 1
Step 2
Step 3
First and last name*
Company*
Email*
Phone