Nombre del parámetro Descripción Unidades de medida
input_status These bits reflect the state of the inputs and indicate which one, if any, triggered an Input Status Changed message. Bit 0: Input 1 change: 0 = Did not trigger message, 1 = Triggered message. Bit 1: Input 1 state: 0 =
Closed, 1 = Open Bit 2: Input 2 change: 0 = Did not trigger message, 1 = Triggered message Bit 3: Input 2 state: 0 = Closed, 1 = Open.
msg_sub_type Message sub-type code.
vibr Value 1 = Unit is in a state of vibration. Value 0 = Unit is not in a state of vibration.
gps_fix_2d Value 1 = GPS data reported is from a 2D fix. (Only 3 satellites were used in the fix.) Value 0 = GPS data reported is from a 3D fix.
motion Value 1 = Device was In-Motion when the message was transmitted. Value 0 = Device was At-Rest when the message was transmitted.
num_tries Number of Transmissions (1 to 15 Transmissions)
min_trans_interval Minimum Interval between transmission attempts ( 5 second resolution) Default is 300 seconds
max_trans_interval Maximum Interval between transmission attempts, Default is 600 seconds
gps_mean_search_time Unsigned binary count in seconds for mean GPS search to acquire
gps_fails Unsigned binary count of failed GPS attempts since last Diagnostic message
alarm Alarm Statistics
alarm1_count Alarm2 since last message (b7=0) / accum hours (b7=1)
alarm2_count Alarm3 since last message (b7=0) / accum hours (b7=1)
transmissions Transmissions since last statistics message
input№_undesired_state_time Accumulated time that Input 1 has been in its undesired state with a resolution of 10 minutes. For example: 1 hour would be represented as a value of 6, 2 hours as a value of 12, etc. This resolution results in a rollover rate of a total time accumulation of approximately 1.25 years. (OxFFFF means that Input 1 Accumulate has been turned off)
vibration_time Accumulated time that the SMARTONE has been in a State of Vibration with a resolution of 10 minutes. For example: 1 hour would be represented as a value of 6, 2 hours as a value of 12, etc. This resolution results in a rollover rate of a total time accumulation of approximately 1.25 years. (OxFFFF means that Input 1 Accumulate has been turned off)
input№_switches_number The total number of openings or closings of input 1 as selected by the user. (OxFF means that Input 1 Accumulate has been turned off)
transms_num Number of transmissions per burst.
bat Battery Condition. 0 = Good battery. 1 = Replace Battery
gps GPS Subsystem Fault. 0 = GPS system OK. 1 = Fault.
transmt Transmitter Subsystem Fault. 0 = Transmitter OK. 1 = Fault.
sched Scheduler Subsystem Fault. 0 = OK. 1 = Fault.