Inmarsat Gateway

Inmarsat Gateway
Fabricante: Inmarsat
Discusión en el foro

Cantidad de unidades

11
En línea
39
Total

Para que el sistema de rastreo Wialon identifique los datos de Inmarsat Gateway en el diálogo de configuración de la unidad, indique los siguientes datos :

Tipo de dispositivo: Inmarsat Gateway
ID único: custom

En el centro de servicio Wialon se utilizan 39 unidades Inmarsat Gateway — es 0.04% de la cantidad total de dispositivos Protocolo de repetidor conectados.

La gráfica representa la cantidad de conexiones en el centro de servicio Wialon en los últimos 30 días:

Nombre del parámetro Descripción Unidades de medida
hardwareVariant​

This field indicates the terminal type. 1 – IDP terminal All other values are reserved

bootLoaderMajor The major version number of the installed boot loader
bootLoaderMinor The minor version number of the installed boot loader
bootLoaderPatch The patch level number of the installed boot loader
firmwareMajor The major version number of the installed base firmware
firmwareMinor The minor version number of the installed base firmwarer
firmwarePatch The patch level number of the installed base firmware
uptime The number of seconds the terminal has been in continuous operation since reset
timeOfDay The current date and time, expressed as number of seconds since the epoch
LSFUptime The number of seconds the Lua Services Framework has been running
powerSaveTime The number of seconds the terminal has been in power save mode since reset
sin​

The SIN

enabled Whether the service is currently enabled
proplist A list of properties for that service
time The new date and time, expressed as number of seconds since the epoch
extPowerPresent external power
batteryVoltage voltage of battery
externalVoltage external voltage
powerOnReason power on reason
autoPowerOnConfig auto power on config
success success
error error
batteryType Type of battery
min min
data The data to be sent out
fix_type fixType
port#_cfg Config of port where #-number of port
port#_value value of port where #-number of port
current_temp currentTemperature
pwr_ext inputPowerVoltage
dte_connected DTEConnected
cmd_success Whether the command was successfully executed
msg_sin sin of msg
msg_min min of msg
region_name name of region
ignition

1 - ignition on
0 - ignition off

comm_channel comm_channel
event_name name of event
gprs_channel gprs channel

Otros dispositivos del fabricante

Contacte con Wialon y logre los objetivos más ambiciosos con la telemática

Por favor, llene la solicitud para iniciar el trabajo con Wialon

Paso 1
Paso 2
Paso 3
Nombre y apellido*
Compañía*
Email*
Teléfono