Queclink GV501LG

Queclink GV501LG
Forum Discussion

Number of units

0
Online
8
Total
Features Queclink GV501LG:
  • 2G
  • 3G
  • 4G/LTE
  • Blackbox
  • BLE enabled

The following data should also be added to Queclink GV501LG unit properties section of Wialon GPS tracking software :

Device type: Queclink GV501LG
Unique ID: imei

Specify the following parameters in configuration software or configuration Queclink GV501LG for use in Wialon Hosting :

Server port: 22270

8 units of Queclink GV501LG device type are connected to Wialon Data Center. This represents 0.01% of all OBD trackers connected.

Below chart represents the dynamic of connections in the last 30 days:

Parameter name Description Units
device_type

The device type refers to the terminal model. In general, the device type will not change due to hardware or firmware upgrades.

protocol_ver For example, 0001H means V1, 000CH means V12, and 007BH means V123.The protocol version number.
cust_ver For example, 01H means V1, 0CH means V12, and 7BH means V123. This version number is reserved for user customization.
count_number

A self-increasing count number in each report, it begins from 0000H and increases by 1 for each report, and it rolls back after FFFFH. The count number is accumulated according to the order in which the reports are sent, not in the order in which the reports are generated. After the terminal is restarted, the count number will not restart from 0000H, but will continue to accumulate based on the count before restarting.

profile_id

Used to indicate the profile the terminal was in when the record or report was generated.

name

The name of the terminal device.

serial_number The unique serial number of the terminal device.
trig_time

Used to record the time when the event occurred.

report_cnt

The number of reports stored in the terminal that were not sent to the backend server. Expressed as a 16-bit unsigned integer.

motion_status

Motion Status The current motion status of the terminal.

  • 00H-The terminal is motionless now.
  • 01H-The terminal is being moved now.
  • 02H-Unknown. The terminal is detecting motion now.


tow_status

The vehicle's current tow status.

    • 00H-The vehicle is not being towed now.
    • 01H-Fake Tow. The vehicle is ignition off and it is likely to be being towed now.
    • 02H-Tow. The vehicle is being towed now.

    ign_status

    The vehicle's current ignition status.

    • 00H-The vehicle is ignition off now.
    • 01H-The vehicle is ignition on now.
    • 02H-Unknown. The terminal is checking whether the vehicle is on or off.

    total_mileage Total mileage. Expressed as a 32-bit unsigned integer and the unit is meter.
    cur_mileage

    The accumulated mileage of vehicle since latest ignition on. Expressed as a 32-bit unsigned integer and the unit is meter.

    vin Vehicle Identification Number. In particular, ALL 00H means that the terminal cannot obtain this data currently.
    trip_fuel_cons The fuel consumption of vehicle since latest ignition on. Expressed as a 16-bit unsigned integer and the unit is 0.1L. In particular, FFFFH means that the terminal cannot obtain this data currently.
    eng_cool_tmp The engine coolant temperature. Expressed as a 16-bit signed integer and the unit is degrees Celsius. In particular, FFFFH means that the terminal cannot obtain this data currently.
    throttle_pos

    Absolute throttle position (not "relative" or "learned" throttle position). It indicates a percentage value of the throttle position sensor. In particular, FFH means that the terminal cannot obtain this data currently.

    eng_rpm

    Revolutions per minute (RPM) of the engine. Expressed as a 16-bit unsigned integer and the unit is rpm. In particular, FFFFH means that the terminal cannot obtain this data currently.

    eng_load

    Calculated load value. Percent of maximum available engine torque. In particular, FFH means that the terminal cannot obtain this data currently.

    mil_status

    Malfunction Indicator Lamp (MIL) Status.

    • 00H-MIL OFF.
    • 01H-MIL ON.
    • 02H-Unknown.

    wifi_clients_cnt Number of clients connected to Wi-Fi. Expressed as an 8-bit unsigned integer. In particular, FFH means that the terminal cannot obtain this data currently.
    fix_state
    • 0-Off. GNSS is not working at the moment. In this case, the 'longitude', 'latitude', 'speed'(if any), 'UTC time'(if any) etc. are the same as the last valid positioning.
    • 1-No fix. GNSS worked but could not get the position. In this case, the 'longitude', 'latitude', 'speed'(if any), 'UTC time'(if any) etc. are the same as the last valid positioning.
    • 2-Fix. GNSS worked and got the accurate location. The values of all fields are reliable to use.
    fix_mode
    • 00-2D GNSS fix.
    • 1-3D GNSS fix.
    hdop

    Horizontal Dilution of Precision.

    roaming
    • 0-Registered to the home network.
    • 1-Registered to a roaming network.
    acc_tech
    • 0-GSM
    • 1-UMTS
    • 8-LTE Cat-4
    band
    • 0-800MHz
    • 1-850MHz
    • 2-900MHz
    • 3-1800MHz
    • 4-1900MHz
    • 5-2100MHz
    csq_rssi
    • 0 - -113 or less
    • 1 - - 111
    • from 2 to 30 - from -109 to -53
    • 31 - -51 or grater
    • 99 - Not known or not detectable
    bit_err_rate Channel bit error rate (in percent). In particular, 63H (i.e. 99) means "Not known or not detectable".
    conn_status

    Whether the external power supply is connected.

    • 00H-Not connected.
    • 01H-Connected.

    voltage

    The external power supply voltage of the terminal device. This field is only valid when Connection Status is 01H (Connected).

    imsi International Mobile Subscriber Identity. In particular, ALL 00H means that the terminal cannot obtain these data currently.
    iccid

    Integrated Circuit Card Identity. In particular, ALL 00H means that the terminal cannot obtain these data currently.

    geo_id

    The ID of Geo-fence.

    geo_status

    GEO Status The current status of Geo-fence.

    • 0-The terminal is inside of Geo-fence now.
    • 1-The terminal is outside of Geo-fence now.

    tow_mileage

    The accumulated mileage from the beginning of the vehicle to be towed to the present or stopped.

    idling_status

    The vehicle's current idling status.

    • 00H-The vehicle is not idling.
    • 01H-The vehicle is idling.
    • 02H-Unknown.

    idling_dur Duration of idling status.
    pfc_mode

    Indicates the working mode of Parking-fence function.

    • 0-Disable.
    • 1-Enable (Automatically triggered always).
    • 2-Enable (Automatically triggered once).

    pfc_status

    Indicates the current status of the Parking-fence.

    • 0-No Parking-fence is generated.
    • 1-The Parking-fence is generated (the vehicle is inside).
    • 2-The Parking-fence is canceled (the vehicle is outside).

    pfc_radius The radius of the circular Parking-fence region.
    pfc_lon Indicates the longitude of the center of the circular Parking-fence region.
    pfc_lat

    ndicates the latitude of the center of the circular Parking-fence region.

    self_tst_tm Record the moment the data is updated. Difference, in seconds, between the current local time and midnight, January 1, 1970.
    self_tst_conn

    Connectivity Used to indicate the connectivity of the corresponding component. Different bits correspond to different components. A bit value of 1 means that the connectivity of the corresponding component is abnormal, otherwise it means that the connectivity of the corresponding component is normal. The components corresponding to the bits are as follows:

    • Bit0-MCU
    • Bit1-Modem
    • Bit2-Reading IMEI
    • Bit3-SIM/eSIM
    • Bit4-GNSS
    • Bit5-G-Sensor
    • Bit6-External Flash
    • Bit11-Reading external power voltage
    • Bit13-OBD
    • Other bits-Reserved, set to 0 by default

    hbi_type

    Indicates which type of harsh behavior event occurred.

    • 0-Normal.
    • 1-Harsh acceleration.
    • 2-Harsh deceleration.
    • 3-Harsh cornering.
    • 255-Unknown.

    More devices from the manufacturer

    Contact Wialon and achieve the most ambitious goals with telematics

    Fill out a request form to get started with Wialon

    Step 1
    Step 2
    Step 3
    First and last name*
    Company*
    Email*
    Phone