NT-183W

NT-183W
Manufacturer: Nyitech
Forum Discussion

Number of units

70
Online
514
Total
Features NT-183W:
  • Blackbox
  • GLONASS support
Supported in Wialon:
  • Remote management via GPRS
  • Communication via TCP

The following data should also be added to NT-183W unit properties section of Wialon GPS tracking software :

Device type: NT-183W
Unique ID: serial

Specify the following parameters in configuration software or configuration NT-183W for use in Wialon Hosting :

Server port: 21130

514 units of NT-183W device type are connected to Wialon Data Center. This represents 0.65% of all OBD trackers connected.

Below chart represents the dynamic of connections in the last 30 days:

Parameter name Description Units
vin VIN code
random_number Platform customized Random No
pids_number Supported PID numbers
event_code Event Code
dtc_type

DTC type:
0 - Stored or Historical DTC
1 - Pendng or current DTC

dtc_number DTC numbers
dtcN DTC Status witn number N
fw_ver

Firmware version

set_params_number Setting Parameter numbers
paramN Parameter value with number N
markers

Multiple markers:
0 - Last Inquiry Reply event packet.
>= 1 - not last Inquiry Reply event packet

params_number

Inquiry Success Parameter numbers

total_mileage Current total mileage m
alarm_tag

Alarm Tag:
0 - Alarm end
1 - New alarm

alarm_number

Alarm No:
1 - MIL on
2 - Idle Engine
3 - Fatigue Driving
4 - Low voltage
5 - High temperature
6 - Towing
7 - Speeding
8 - High RPM
15 - ACC Status(Alarm Tag: 0- ACC OFF, 1 - ACC ON)

Alarms with only New Alarm state:
9 - Hard acceleration
10 - Hard braking
11 - Quick turn
12 - Power on
13 - Power off
14 - SOS

alarm_threshold

Alarm Threshold

alarm_value The same as Alarm Threshold
alarm_time_gmt0 UNIT RTC time when alarm occurs
obd_module_ver OBD module version
hw_ver UNIT hardware version
cur_trip_fuel_cons

Current trip fuel consumption

L
cur_trip_mileage

Current trip mileage

m
cur_trip_duration

Current trip duration

ms
terminal_voltage Terminal voltage V
protocol_code

Vehicle protocol code

acc

ACC:
1 - ON
0 - OFF

front_back_accelN

Front-back acceleration witn number N:
Front = “+”
back = “-”

4 mg
left_right_accelN

Left-right acceleration witn number N:
Left= “+”
Right= “-”

4 mg
up_down_accelN

Up-down acceleration with number N:
Up = “+”
Down = “-”

4 mg
pidN Value of PID with number N
location_fix

Location fix:
0 - Not fixed
1/3 - fixed

Contact Wialon and achieve the most ambitious goals with telematics

Fill out a request form to get started with Wialon

Step 1
Step 2
Step 3
First and last name*
Company*
Email*
Phone