Dozor X2

Dozor X2
Forum Discussion

Number of units

1
Online
3
Total

The following data should also be added to Dozor X2 unit properties section of Wialon GPS tracking software :

Device type: Dozor X2
Unique ID: serial

Specify the following parameters in configuration software or configuration Dozor X2 for use in Wialon Hosting :

Server port: 20297

3 units of Dozor X2 device type are connected to Wialon Data Center. This represents 0% of all AVL Hardware connected.

Below chart represents the dynamic of connections in the last 30 days:

Parameter name Description Units
acc Gradation battery voltage 0 - 4
adcX Analog sensor, X - number of sensor
balance Balance of subscriber
btnX Code iButton N3 and N4 , X - number of iButton
can_ff Full fuel consumption l
can_f Flags of states
can_fl Level of fuel in the tank %
can_pr Total mileage
can_pX , X - number of sensor
can_tc Engine temperature °C
can_wt The complete operating time of the engine h
canX Value of CAN, X - identifier of a message
cntX Frequency sensor, X - number of sensor
coruu_X Instant value of the phase active power, X - number of phase
delay Time with you last press operator on any of the buttons s
driver_id The value of the RFID reader
etope_X Energy consumed by tariff, X - number of tariff
fl1 Status bit
frequ The value of the mains frequency
fuel_llcX Fuel sensor, X - number of sensor
ign Ignition status
keyX iButton key, X - number of key
llcX Fuel sensor, X - number of sensor
nav_des Type of navigation solution
pict Date/Time of creation a photo
power The instantaneous value of the total active power
powpp_X The angles between vectors voltage phases, 1 - A and B, 2 - B and C, 3 - C and A
report_type Event that triggered the formation of the report
rfid_event Event of RFID reader
sats_glonass Number of satellites Glonass
sats_gps Number of satellites GPS
status User status
stay_balance Status of balance
tempX Temperature sensor, X - number of sensor °C
time_valid Time valid status
tpX Fuel sensor, X - number of sensor
ver Firmware version
volta_X The RMS voltage, X - number of phase
float_paramX_Y
  • X - parameter counter
  • Y - device address
text
int_paramX_Y
  • X - parameter counter
  • Y - device address
int32
uint_paramX_Y
  • X - parameter counter
  • Y - device address
uint32
len_param Length of parameters
mode Mode of parameters
data_state Status of data
device_address Device address

Contact Wialon and achieve the most ambitious goals with telematics

Fill out a request form to get started with Wialon

Step 1
Step 2
Step 3
First and last name*
Company*
Email*
Phone